Hach Surface Scatter 6 User Manual

Posted By admin On 16.01.20
Advertising
  1. Hach Surface Scatter 6 Turbidimeter
  2. Hach Surface Scatter 6 Turbidimeter Manual

36

The Hach Surface Scatter 7 sc Turbidimeter (SS7) is uniquely designed so that the light source and photocell never come in contact with the sample. In fluids with high loads of suspended solids this makes sample cell cleaning and replacement unnecessary. Durable-manufactured with corrosion/heat-resistant materials for extended life.

Mortal kombat x download free. That’s when I started to get suspicious that not every card was available in the pack, or that the drop rates were structured to increase once you get a character maxed out.I contacted WB games about this, and thus began a 4 day long email thread in which they would email me back approximately once a day.

The Surface Scatter 7 sc High Range Turbidimeter with sc200 controller offers superior performance features. It measures a turbidity range from 0 to 9999 NTU. Includes calibration cylinder, 4000 NTU Formazin, installation accessories, and instruction manual. Hach-Lange SURFACE SCATTER 7 sc Turbidimeter User Manual. Maintenance 6.4.3 detector assembly replacement. Hach-Lange Equipment. Hach-Lange SURFACE SCATTER 7 sc Turbidimeter User Manual. Troubleshooting. Hach-Lange Equipment. Manuals Directory ManualsDir.com - online owner manuals library. Hach-Lange manuals. SURFACE SCATTER 7 sc Turbidimeter.

  • Surface Scatter 7 sc (SS7 sc) Sensor Assembly (Instrument Only) Contact Us Login. Hach Australia. Surface Scatter® 7 sc Turbidimeter User Manual DOC09: English US: 2 MB: 2012-05. Edition; Turbidity Hach Method explained from Water Analysis Handbook: English US: 96 KB: 2011-04: Ed 6: Software/Firmware.
  • Hach-Lange SURFACE SCATTER 7 sc Turbidimeter User Manual. 6 calibration and verification history, Operation. Hach-Lange Equipment. Manuals Directory ManualsDir.com - online owner manuals library. Hach-Lange manuals. SURFACE SCATTER 7 sc Turbidimeter. Manual 6 calibration and verification history.
  • Hach Surface Scatter 6 Turbidimeter Manual (Page 49/64)Instruction Manual / User Guide for Hach-Lange SURFACE SCATTER 7 sc pdf manual Hach-Lange - SURFACE SCATTER 7 sc Turbidimeter. Text mode Table 6. From the Main Menu, select SENSOR DIAG and confirm. Contact your local Hach sales representative to configure.

Operation

9. When the displayed turbidity value is stable, confirm to select

the measured reading. After confirming the reading:

Hach Surface Scatter 6 Turbidimeter

GOOD VER! will be displayed if the verification is good,
with an option to continue or to abort. Confirm to continue.
Enter the operator initials and confirm.

BAD VER! will be displayed if the verification is bad, with an
option to repeat or exit. To repeat the verification, confirm to
return to the VALID SN screen (step

6

).

10. Open the SS7 sc to remove the plate. Restart the sample flow

and close the door. Confirm to return the instrument to
measurement mode.

Note: After confirmation of return to measurement mode, the instrument
will equilibrate for 2 minutes before the output mode changes. Instrument
measurements will show on the display, but the value will flash and a “OUT
MODE WARN” warning will display until the 2-minute equilibration period
is complete.

5.5.4.1 Care of standardization plates

Clean standardization plates to remove fingerprints, dust and dirt.

Clean plates using water and dry with a clean,
lint-free cloth.

Do not use abrasive cleaners or cleaning solvents.

Store the plates in a clean, dry place to prevent scratching or
damage. Replace the plates if they become scratched or broken.

5.6 Calibration and verification history

The calibration and verification history logs contain information on
the last 12 calibrations and the last 12 verifications. The calibration
history log shows the gain value, the time and date of the
calibration and the initials of the operator performing verification.

Hach Surface Scatter 6 Turbidimeter Manual

Note: Restoring default settings from the DIAG/TEST menu will return the
turbidimeter to its non calibration state (gain = 1.0) but it will not remove the
previous calibration history from memory.

The calibration history log is accessed from the Calibrate menu.
The verification history log is accessed from the Verification menu
(a submenu of the Calibrate menu).

Each verification history entry shows the serial number of the
verification device, the value of the verification standard, the time
and date of the verification and the initials of the operator
performing the verification.

To view calibration history:

1. From the Main Menu, select SENSOR SETUP and confirm.

2. If multiple sensors are attached to the controller, choose

SELECT SENSOR>SS7 SETUP and confirm.

3. Select CALIBRATE and confirm.

4. Select CAL HISTORY and confirm. The most recent calibration

will be displayed on the screen.